DRO-43-TSL-100 | ZnSe Singlet F-Theta Scan Lens – 43mm Diameter × 100mm Focal Length | AR Coated @ 10.6µm
DRO-43-TSL-100 | ZnSe Singlet F-Theta Scan Lens – 43mm Diameter × 100mm Focal Length | AR Coated @ 10.6µm is backordered and will ship as soon as it is back in stock.
Care information
Care information
High care information about CO2 laser lenses, fiber laser protective windows, and
fiber laser lenses is essential to ensure the optimal performance and longevity
of these critical components in laser systems. Here are some key points to consider:
CO2 Laser Lenses:
Cleaning:
Regularly clean CO2 laser lenses to remove dust, debris, and residue. Use a
soft, lint-free cloth or lens cleaning tissue. Avoid using abrasive materials
that may scratch the lens.
Handling:
Always handle CO2 lenses with clean hands or lint-free gloves to avoid transferring oils or contaminants onto the lens surface.
Storage:
Store lenses in a clean, dry, and dust-free environment to prevent damage and
maintain their integrity.
Alignment:
Properly align CO2 lenses within the laser system to ensure efficient laser
beam delivery and focus.
Inspection:
Regularly inspect lenses for signs of damage, scratches, or deterioration.
Replace any damaged or worn lenses promptly.
Fiber
Laser Protective Windows:
Cleaning:
Clean fiber laser protective windows with care to avoid scratches. Use a gentle
cleaning solution and a soft, lint-free cloth.
Protection:
Keep protective windows in place when the laser system is not in use to prevent
contamination and damage.
Replacement:
If protective windows become damaged, replace them immediately to maintain
laser system safety and performance.
Fiber Laser Lenses:
Cleaning:
Clean fiber laser lenses carefully to prevent damage. Use a lens cleaning
solution and a soft, lint-free cloth or lens tissue.
Handling:
Handle fiber laser lenses with care to avoid fingerprints, oils, or scratches
on the lens surface.
Alignment:
Properly align fiber laser lenses to ensure accurate laser beam focusing and
efficient performance.
Inspection:
Regularly inspect fiber laser lenses for signs of wear, damage, or contamination. Replace any compromised lenses promptly.
Environmental Considerations: Be mindful of environmental factors such as temperature and
humidity, as extreme conditions may affect lens performance.
Overall,
maintaining high care and attention to detail when handling, cleaning, and
storing CO2 laser lenses, fiber laser protective windows, and fiber laser
lenses will enhance their longevity and contribute to the smooth and reliable
operation of your laser systems. Always follow the manufacturer's guidelines
and best practices for each specific component to ensure optimal results.
Delivery and Shipping
Delivery and Shipping
FOR ITEMS IN STOCK:
Orders placed before 2:00 pm EST/EDT on a business day
(Monday - Friday) will ship the same day.
Orders placed after 2:00 pm EST/EDT may not be be shipped
until the next business day.
Our business hours are Monday to Friday, 9 am-4:30 pm.
Orders placed after business hours will not be processed
until the next business day.
Orders placed during the weekend (Saturday - Sunday) or
holiday will be shipped on the next business day.
All packages are shipped FOB ORIGIN – These shipping terms
are characteristic of a “SHIPMENT CONTRACT” and the seller bears the expense
and risk of putting the goods in the possession of the carrier. Title transfers to the buyer at the point when the goods leave the shipper’s loading dock but reverts back to the seller if the buyer follows the correct procedures of notifying the seller of “breach” by “rightfully revoking cceptance.” Even if “breach” has occurred, the buyer remains responsible for filing “carrier loss
claims.”
Product Description
This Zinc Selenide (ZnSe) Singlet F-Theta Scan Lens is designed for CO₂ laser scanning systems operating at 10.6µm.
Featuring a 43mm diameter, 100mm focal length, and 2mm edge thickness, this single-element scan lens is designed to provide flat-field focusing for laser scanning applications.
Manufactured from Zinc Selenide (ZnSe), the lens features an anti-reflective coating on both surfaces (AR/AR) optimized for 10.6µm to reduce surface reflections and improve optical transmission.
This lens is offered as a replacement for Infosight® ITM27157, subject to verification of the original equipment's optical and mechanical specifications.
Technical Specifications
| Specification | Details |
|---|---|
| Model / SKU | DRO-43-TSL-100 |
| Product Type | Singlet F-Theta Scan Lens |
| Material | Zinc Selenide (ZnSe) |
| Lens Design | Single Element (Singlet) |
| Diameter | 43mm (1.693") |
| Diameter Tolerance | +0.00mm / -0.10mm |
| Focal Length | 100mm (3.937") |
| Edge Thickness | 2.0mm (0.079") |
| Coating | AR/AR (Both Surfaces) |
| Coating Wavelength | 10.6µm |
| Field Type | Flat Field |
| Replacement Reference | Infosight® ITM27157 |
Optical Characteristics
Single-Element F-Theta Scan Lens
-
Zinc Selenide (ZnSe) optical material
-
Designed for CO₂ laser scanning applications
-
100mm nominal focal length
-
Single-element optical design
-
Flat-field focusing configuration
-
Anti-reflective coating on both surfaces at 10.6µm
-
Offered as a replacement for Infosight® ITM27157
Applications
-
CO₂ laser scanning systems
-
Laser marking and engraving equipment
-
Galvanometer-based laser scanning systems
-
Flat-field laser focusing applications
-
Industrial laser processing
-
Replacement optical components for compatible Infosight equipment
Replacement Compatibility
Replacement Reference: Infosight® ITM27157
This lens is offered as a replacement for the referenced Infosight optical component.
Before ordering, verify the original lens diameter, focal length, edge thickness, coating wavelength, mounting dimensions, and optical design.
Compatibility with a specific machine should be confirmed before installation.
Infosight® is a trademark of its respective owner. This product is not represented as an original Infosight-manufactured component.
Important Compatibility Information
F-Theta scan lenses are designed for specific optical scanning configurations. Matching the diameter and focal length alone does not guarantee compatibility.
Verify the required scan field, beam diameter, scan angle, mounting configuration, and working distance before selecting a replacement lens.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
KeyFeatures of Our Products: